The legal duty sits with the landlord, but the questions come to you. How long has the tenant got to get a copy? Does a check in October keep the December date? Is the old EICR still good for a new tenant? This guide sets out the gas and electrical rules for rented homes as they stand on 17 October 2026, mainly for England, with short notes on Wales, Scotland and Northern Ireland.
The annual gas safety check
Under regulation 36 of the Gas Safety (Installation and Use) Regulations 1998, a landlord must have each gas appliance and flue they provide checked within 12 months of it being installed, then at intervals of no more than 12 months. The check must be done by a Gas Safe registered engineer. The rule applies in England, Wales and Scotland.
HSE’s guidance for landlords says every permanent and portable gas appliance and flue in the property needs the annual check, meaning the ones the landlord provides. “CP12” is the old trade name; the law calls the result a gas safety record.
Copies for tenants
The landlord must give:
- existing tenants a copy within 28 days of the check
- new tenants a copy of the last record before they move in
- for a stay of 28 days or less, such as a holiday let, a copy displayed prominently in the property instead
So the “display it” option is for occupation of 28 days or less, not for any short tenancy.
How long records are kept
Since 6 April 2018, the landlord keeps each record until two further checks of that appliance or flue have been done (the 2018 amendment). HSE puts it as keeping records for at least two years. The easy way to explain it: keep every record for at least 2 years, or until two more checks have been done, whichever is longer.
Checking up to two months early
Regulation 36A, added in April 2018, lets a landlord have the check done in the 2 months before the deadline and treat it as done on the deadline date. HSE’s landlord FAQ confirms the original deadline is kept.
Say a landlord’s record runs out on 15 December 2026. A check in November keeps 15 December 2027 as the next deadline. A check in September, more than 2 months early, resets the anniversary to the September date.
There’s also a one-off option for a new appliance: the first check can be pushed up to 2 months past its normal date so it lines up with the property’s other appliances. HSE says you can only stretch that gap by two months.
What the gas safety record must contain
Regulation 36 lists what the record must show:
- the date of the check
- the address of the property
- the name and address of the landlord, or their agent
- a description and the location of each appliance and flue checked
- any safety defect found and the action taken to put it right
- confirmation that the checks in regulation 26(9) were carried out
- the name, registration number and signature of the engineer who did the check
The tenant’s copy can leave out the signature if it says a signed copy is available to inspect.
Appliances the tenant owns
If a tenant brings their own appliance, such as a gas cooker, the landlord isn’t responsible for the appliance itself. HSE’s FAQ says the landlord does have responsibilities for parts of the installation and the pipework. HSE recommends including all flues connected to gas appliances in the check. Where there’s no appliance at all but gas pipework runs through the property, there’s no annual check, but the landlord must still keep the pipework safe.
For more on the records you issue as a gas engineer, see our page for gas engineers.
Electrical safety in privately rented homes in England
The Electrical Safety Standards Regulations 2020 (SI 2020/312), as amended by SI 2025/1043, require landlords to have the electrical installation inspected and tested by a qualified person at least every 5 years, or sooner if the last report says so. Since 1 November 2025, the inspection and test must also be done before a new tenancy starts.
Copies and deadlines
The landlord must give a copy of the report to:
- existing tenants, within 28 days of the inspection
- new tenants, before they move in
- a prospective tenant, within 28 days of a written request
- the local housing authority, within 7 days of a written request
The landlord keeps a copy until the next inspection and test.
Remedial work and fines
If the report says remedial work is needed, the landlord must have it done within 28 days, or sooner if the report says so. They then give the tenant and the council written confirmation within 28 days of the work being finished. The regulations still refer to further investigation, which BS 7671 Amendment 4 now treats differently; our guide to the EIC and the EICR explains the codes.
The gov.uk guidance says councils can fine a landlord up to £40,000 for a breach. Regulation 11 raised the cap from £30,000 on 1 November 2025.
Social rented homes in England
SI 2025/1043 extended the same rules to social landlords. For social tenancies granted from 1 December 2025, the duties apply from the start. For social tenancies granted before then, they apply from 1 May 2026, and the gov.uk guidance says the first inspection must be done before 1 November 2026. That’s two weeks away, so expect late calls from housing associations. Social landlords also have to check electrical equipment they supply with a tenancy every 5 years.
A proposed change, not yet made
A draft amendment for 2026 was laid before Parliament on 13 July 2026. If made, it would update the British Standard reference, remove the references to further investigation, and mean a new tenancy doesn’t need a fresh inspection where a report from the last 5 years exists. It’s meant to start on 30 November 2026. On 17 October 2026 it is proposed, not yet made, so the current rules still apply.
Wales, Scotland and Northern Ireland
The gas rules above, including the two-month window, apply in Wales and Scotland too. The electrical rules differ.
Wales. Under the Renting Homes (Fitness for Human Habitation) (Wales) Regulations 2022, a landlord needs a valid electrical condition report, valid for 5 years from the inspection or less if the report says so. The contract-holder gets a copy within 14 days, not 28.
Scotland. The Repairing Standard guidance needs an EICR before the property is let and at intervals of no more than 5 years. Portable appliances the landlord supplies need an in-service inspection and test (PAT), but tenants’ own don’t. Landlords keep the EICR for six years.
Northern Ireland. Gas safety has its own regulations, enforced by HSENI, and the details differ. Don’t assume the GB two-month early-check rule applies there: we couldn’t confirm it’s in force in Northern Ireland as of 17 October 2026.
The Renters’ Rights Act and the landlord database
The Renters’ Rights Act 2025 didn’t change the gas or electrical safety duties. The government’s roadmap says landlords will upload gas safety, electrical safety and EPC information to the new private rented sector database when they register.
The database launches on 15 December 2026, starting in the West Midlands and rolling out region by region over about 12 months. Every landlord actively letting must be registered by 14 November 2027. Landlords who can’t find last year’s record will be asking you for a copy.
Keeping track of anniversaries
Most landlord work repeats: gas every 12 months, electrics every 5 years or sooner. Note the deadline on every job, and contact the landlord a little over 2 months before it so the check falls inside the early window. For electricians, the next inspection date on the report is the one to diary; our page for electricians covers the certificates you issue.
Quidjob issues landlord gas safety records and EICRs, along with service records, warning notices, minor works certificates and EICs, and reminds you when each one is due again. You can try Pro free for 14 days, with no card.
Official sources
- Gas Safety (Installation and Use) Regulations 1998, regulation 36 (landlords’ duties)
- Gas Safety (Installation and Use) Regulations 1998, regulation 36A (checks up to two months early)
- Gas Safety (Installation and Use) (Amendment) Regulations 2018, regulation 5
- HSE: Gas safety checks, what landlords need to do
- HSE: Gas safety record
- HSE: Landlords’ frequently asked questions
- HSE: Gas safety checks, what if
- Electrical Safety Standards in the Private Rented Sector and Social Rented Sector (England) Regulations 2020, regulation 3
- Electrical Safety Standards Regulations 2020, regulation 11 (financial penalties)
- Electrical Safety Standards (Extension to the Social Rented Sector) Regulations 2025 (SI 2025/1043)
- GOV.UK: Electrical safety standards in the private and social rented sectors, guidance
- Draft Electrical Safety Standards (England) (Amendment) Regulations 2026
- Renting Homes (Fitness for Human Habitation) (Wales) Regulations 2022
- Scottish Government: Repairing Standard statutory guidance for landlords, electrical safety
- Renters’ Rights Act 2025
- GOV.UK: Implementing the Renters’ Rights Act 2025, our roadmap
- GOV.UK: Stronger protections and greater confidence for renters
Last checked 17 October 2026 against legislation.gov.uk, hse.gov.uk, GOV.UK, gov.scot. General guidance for UK businesses, not legal, tax or financial advice. For your own situation, ask HMRC, an accountant or a solicitor.