Choose which optional cookies we may use. You can change this any time from “Cookie settings” at the foot of every page. Cookie policy

Certificates

Landlord gas safety and EICR rules: a guide for gas engineers and electricians

Landlords carry the legal duty, but they ask you what it means. Here are the gas and electrical rules for rented homes as they stand in October 2026, so you can explain them on the doorstep.

Published · 6 min read

The legal duty sits with the landlord, but the questions come to you. How long has the tenant got to get a copy? Does a check in October keep the December date? Is the old EICR still good for a new tenant? This guide sets out the gas and electrical rules for rented homes as they stand on 17 October 2026, mainly for England, with short notes on Wales, Scotland and Northern Ireland.

The annual gas safety check

Under regulation 36 of the Gas Safety (Installation and Use) Regulations 1998, a landlord must have each gas appliance and flue they provide checked within 12 months of it being installed, then at intervals of no more than 12 months. The check must be done by a Gas Safe registered engineer. The rule applies in England, Wales and Scotland.

HSE’s guidance for landlords says every permanent and portable gas appliance and flue in the property needs the annual check, meaning the ones the landlord provides. “CP12” is the old trade name; the law calls the result a gas safety record.

Copies for tenants

The landlord must give:

  • existing tenants a copy within 28 days of the check
  • new tenants a copy of the last record before they move in
  • for a stay of 28 days or less, such as a holiday let, a copy displayed prominently in the property instead

So the “display it” option is for occupation of 28 days or less, not for any short tenancy.

How long records are kept

Since 6 April 2018, the landlord keeps each record until two further checks of that appliance or flue have been done (the 2018 amendment). HSE puts it as keeping records for at least two years. The easy way to explain it: keep every record for at least 2 years, or until two more checks have been done, whichever is longer.

Checking up to two months early

Regulation 36A, added in April 2018, lets a landlord have the check done in the 2 months before the deadline and treat it as done on the deadline date. HSE’s landlord FAQ confirms the original deadline is kept.

Say a landlord’s record runs out on 15 December 2026. A check in November keeps 15 December 2027 as the next deadline. A check in September, more than 2 months early, resets the anniversary to the September date.

There’s also a one-off option for a new appliance: the first check can be pushed up to 2 months past its normal date so it lines up with the property’s other appliances. HSE says you can only stretch that gap by two months.

What the gas safety record must contain

Regulation 36 lists what the record must show:

  • the date of the check
  • the address of the property
  • the name and address of the landlord, or their agent
  • a description and the location of each appliance and flue checked
  • any safety defect found and the action taken to put it right
  • confirmation that the checks in regulation 26(9) were carried out
  • the name, registration number and signature of the engineer who did the check

The tenant’s copy can leave out the signature if it says a signed copy is available to inspect.

Appliances the tenant owns

If a tenant brings their own appliance, such as a gas cooker, the landlord isn’t responsible for the appliance itself. HSE’s FAQ says the landlord does have responsibilities for parts of the installation and the pipework. HSE recommends including all flues connected to gas appliances in the check. Where there’s no appliance at all but gas pipework runs through the property, there’s no annual check, but the landlord must still keep the pipework safe.

For more on the records you issue as a gas engineer, see our page for gas engineers.

Electrical safety in privately rented homes in England

The Electrical Safety Standards Regulations 2020 (SI 2020/312), as amended by SI 2025/1043, require landlords to have the electrical installation inspected and tested by a qualified person at least every 5 years, or sooner if the last report says so. Since 1 November 2025, the inspection and test must also be done before a new tenancy starts.

Copies and deadlines

The landlord must give a copy of the report to:

  • existing tenants, within 28 days of the inspection
  • new tenants, before they move in
  • a prospective tenant, within 28 days of a written request
  • the local housing authority, within 7 days of a written request

The landlord keeps a copy until the next inspection and test.

Remedial work and fines

If the report says remedial work is needed, the landlord must have it done within 28 days, or sooner if the report says so. They then give the tenant and the council written confirmation within 28 days of the work being finished. The regulations still refer to further investigation, which BS 7671 Amendment 4 now treats differently; our guide to the EIC and the EICR explains the codes.

The gov.uk guidance says councils can fine a landlord up to £40,000 for a breach. Regulation 11 raised the cap from £30,000 on 1 November 2025.

Social rented homes in England

SI 2025/1043 extended the same rules to social landlords. For social tenancies granted from 1 December 2025, the duties apply from the start. For social tenancies granted before then, they apply from 1 May 2026, and the gov.uk guidance says the first inspection must be done before 1 November 2026. That’s two weeks away, so expect late calls from housing associations. Social landlords also have to check electrical equipment they supply with a tenancy every 5 years.

A proposed change, not yet made

A draft amendment for 2026 was laid before Parliament on 13 July 2026. If made, it would update the British Standard reference, remove the references to further investigation, and mean a new tenancy doesn’t need a fresh inspection where a report from the last 5 years exists. It’s meant to start on 30 November 2026. On 17 October 2026 it is proposed, not yet made, so the current rules still apply.

Wales, Scotland and Northern Ireland

The gas rules above, including the two-month window, apply in Wales and Scotland too. The electrical rules differ.

Wales. Under the Renting Homes (Fitness for Human Habitation) (Wales) Regulations 2022, a landlord needs a valid electrical condition report, valid for 5 years from the inspection or less if the report says so. The contract-holder gets a copy within 14 days, not 28.

Scotland. The Repairing Standard guidance needs an EICR before the property is let and at intervals of no more than 5 years. Portable appliances the landlord supplies need an in-service inspection and test (PAT), but tenants’ own don’t. Landlords keep the EICR for six years.

Northern Ireland. Gas safety has its own regulations, enforced by HSENI, and the details differ. Don’t assume the GB two-month early-check rule applies there: we couldn’t confirm it’s in force in Northern Ireland as of 17 October 2026.

The Renters’ Rights Act and the landlord database

The Renters’ Rights Act 2025 didn’t change the gas or electrical safety duties. The government’s roadmap says landlords will upload gas safety, electrical safety and EPC information to the new private rented sector database when they register.

The database launches on 15 December 2026, starting in the West Midlands and rolling out region by region over about 12 months. Every landlord actively letting must be registered by 14 November 2027. Landlords who can’t find last year’s record will be asking you for a copy.

Keeping track of anniversaries

Most landlord work repeats: gas every 12 months, electrics every 5 years or sooner. Note the deadline on every job, and contact the landlord a little over 2 months before it so the check falls inside the early window. For electricians, the next inspection date on the report is the one to diary; our page for electricians covers the certificates you issue.

Quidjob issues landlord gas safety records and EICRs, along with service records, warning notices, minor works certificates and EICs, and reminds you when each one is due again. You can try Pro free for 14 days, with no card.

Official sources

Last checked 17 October 2026 against legislation.gov.uk, hse.gov.uk, GOV.UK, gov.scot. General guidance for UK businesses, not legal, tax or financial advice. For your own situation, ask HMRC, an accountant or a solicitor.

Questions

Anything else? Email hello@quidjob.co.uk.

Can a landlord gas safety check be done early without losing the renewal date?

Yes. In England, Wales and Scotland, a check done in the 2 months before the deadline is treated as if it was done on the deadline date, so the anniversary stays the same. A check done more than 2 months early resets the anniversary to the date of that check.

How long must a landlord keep a gas safety record?

The regulations say until two further checks of that appliance or flue have been done. HSE describes it as at least two years. The simplest way to put it to a landlord is to keep every record for at least 2 years, or until two more checks have been done, whichever is longer.

How often does a privately rented home in England need an EICR?

At least every 5 years, or sooner if the last report says so, and since 1 November 2025 before a new tenancy starts. Existing tenants get a copy within 28 days of the inspection, new tenants before they move in, and councils can fine a landlord up to £40,000 for a breach.

Does a landlord have to check a tenant’s own gas cooker?

No. HSE says landlords are responsible for the parts of the installation and pipework, but not for an appliance the tenant owns and the landlord didn’t provide. HSE does recommend including any flues connected to gas appliances in the check.

Did the Renters’ Rights Act change gas or electrical safety checks?

No. The duties to check gas appliances every year and electrics every 5 years are unchanged. What’s new is the private rented sector database, launching from 15 December 2026, where landlords will add gas safety, electrical safety and EPC information when they register.

Send the invoice. Get paid by bank.

Quotes, invoices and bank transfers for UK trades. 14 days free, no card needed.

Start free